Showing 73–81 of 115 results

  • R134a refrigerant gas cylinder in Kenya

    R134a Refrigerant Gas

    R134a refrigerant gas for household fridges, vehicle air conditioning, water dispensers and medium-temperature cold rooms, available in Nairobi with delivery across Kenya.

    • Non-flammable and ozone-friendly
    • Single-component gas, easy to charge
    • For technicians, garages, workshops and contractors

    Call or WhatsApp 0722 664 867 for a quote.

    • Sealed cylinders

    Call or WhatsApp 0722 664 867 for a quote.

  • R22 refrigerant gas cylinder in Kenya

    R22 Refrigerant Gas

    R22 (HCFC-22) was for many years the most common refrigerant in air conditioners, chillers and cold rooms. Many older units across Kenya and East Africa still run on it and need R22 for servicing and leak repairs.

    • For servicing existing R22 systems
    • Sealed cylinders
    • Advice available on alternatives

    Call or WhatsApp 0722 664 867 for a quote.

  • R22 refrigerant gas cylinder for fridges, freezers, cold rooms, and AC systems from Bioflex Insulation Ltd

    R22 REFRIGERANT GAS – 13.6 KG

    High-purity R22 refrigerant gas for fridges, freezers, cold rooms, and air-conditioning systems. Ideal for refilling, installation, and servicing of older refrigeration units across Kenya. Packaged in a secure 13.6 kg steel cylinder for reliable performance.

  • R32 Gas in Kenya for Inverter Air Conditioners Bioflex Insulation supplies genuine R32 refrigerant gas in Kenya to AC installers, HVAC contractors, service technicians, facility managers and appliance service centres. Most new inverter split air conditioners sold in Kenya now run on R32. As more homes, offices, shops and hotels install these units, demand for genuine R32 for installation and servicing keeps growing. We supply R32 together with the copper pipes, Armaflex pipe insulation and tapes needed for every split AC installation. Our own HVAC team also installs and services air conditioning, so we understand the jobs you’re doing. What is R32 Refrigerant? R32 (difluoromethane) is a single-component HFC refrigerant. It’s not a blend, so it boils at one temperature and its makeup never changes, even after a leak. It contains no chlorine, so its ozone depletion potential is zero. R32 is one of the two gases that make up R410A. Used on its own, it carries more heat per kilogram than R410A, so an air conditioner needs a smaller charge and uses less electricity for the same cooling. Its global warming potential is about a third of R410A’s. That’s why most major AC manufacturers have moved their new split and inverter models to R32. R32 is classed as A2L, mildly flammable. It’s hard to ignite and burns slowly, but technicians must handle it with the right tools and precautions. Where R32 Gas Is Used Inverter wall-mounted split air conditioners in homes, apartments, offices and shops Cassette and ceiling-suspended units in restaurants, banks and conference rooms Ducted split systems for open-plan offices and large homes Light commercial AC systems in hotels, clinics and retail outlets Air-to-water heat pumps for hot water and heating Dehumidifiers and portable ACs (newer models) R32 vs R410A vs R22: What’s the Difference? These are the three main AC gases in Kenya today. Here’s how they compare: R22 R410A R32 Type HCFC, single gas HFC blend (R32 + R125) HFC, single gas Ozone depletion (ODP) 0.055 0 0 Global warming (GWP) 1,810 2,088 675 Operating pressure Standard About 1.6 Γ— R22 Similar to R410A Charge needed Standard Standard About 20 to 30 % less than R410A Energy efficiency Lower Good Higher Flammability A1, non-flammable A1, non-flammable A2L, mildly flammable Can it be topped up? Yes Small top-ups only Yes Main use today Servicing older ACs Most installed split and VRF systems New inverter split ACs These gases are not interchangeable. R32 must only be used in equipment designed and labelled for R32. Never put R32 into an R410A or R22 unit, and never put R410A into an R32 unit. Each system’s compressor, oil, safety design and charge are built around one specific gas. How to Tell if Your Air Conditioner Uses R32 Check the nameplate on the outdoor unit. It shows β€œR32” and the factory charge in kilograms. Look for a flammability warning. R32 units usually carry a small flame symbol or an A2L label. Look at the service port. R32 units use the same 5/16" service port as R410A, so always confirm the gas on the nameplate. Check the cylinder. R32 cylinders usually carry a red band or red marking to show the gas is flammable. Always read the label. Signs Your Inverter AC May Be Low on R32 Gas The unit runs but doesn’t cool the room properly The air from the indoor unit feels only slightly cool Ice forms on the indoor coil or the outdoor unit’s suction pipe The unit shows an error code for low pressure, gas shortage or high discharge temperature Your electricity bill goes up with no change in use Oily stains appear at flare joints or valves Low gas always means there’s a leak. Find and repair it before recharging. Because R32 is a single gas, the system can be topped up once the leak is fixed, without recovering the whole charge. Technical Specifications Property R32 Chemical name Difluoromethane (CHβ‚‚Fβ‚‚) Refrigerant type HFC, single component Boiling point (at 1 atm) βˆ’51.7 Β°C Temperature glide 0 Β°C Critical temperature 78.1 Β°C Vapour pressure at 25 Β°C About 16.9 bar (absolute) Ozone depletion potential (ODP) 0 Global warming potential (GWP) 675 ASHRAE safety class A2L, mildly flammable, low toxicity Compatible oil POE or PVE, as the compressor manufacturer specifies Cylinder marking Red band or red marking (flammable gas) Pack size 11.3 kg cylinder Best Practice When Installing and Servicing R32 Systems Use A2L-rated tools. Vacuum pumps, recovery machines and leak detectors must be rated for mildly flammable refrigerants, because ordinary equipment can create sparks. Gauges and hoses must be rated for R32 or R410A pressures. Work in a ventilated area. Keep open flames, sparks and smoking away from the work area. Don’t switch electrical equipment on or off near a suspected leak. Never braze on a charged system. Recover the refrigerant, purge the pipework with nitrogen, then braze with nitrogen flowing through the pipe. Use the right copper. Use refrigeration-grade copper pipe with the wall thickness the AC manufacturer specifies, and make clean flares with an R410A/R32 flaring tool. Pressure test with nitrogen. Check every flare and joint for leaks before you add refrigerant. Pull a deep vacuum. Evacuate to 500 microns or below and confirm the vacuum holds. Moisture damages the oil and compressor. Charge by weight. Weigh in the charge on the nameplate, plus extra for long pipe runs as the manufacturer specifies. R32 can be charged as vapour or liquid because it’s a single gas. Insulate the pipes. Wrap both suction and liquid lines in Armaflex insulation and seal the joints with tape to stop condensation drips and protect efficiency. Using R32 in Kenya’s Climate R32’s efficiency matters most where air conditioners run for long hours, such as Mombasa, Malindi and Lamu on the coast, and hot areas like Garissa, Lodwar and Kisumu. Inverter ACs running on R32 adjust their speed to the cooling load, so they use less power than older fixed-speed units. In dusty or coastal areas, clean the outdoor coils regularly and check the gas charge during routine servicing, because high outdoor temperatures put extra load on the system. Why R32 Is the Future of Split Air Conditioning Under the Kigali Amendment to the Montreal Protocol, countries are gradually phasing down HFC gases with high global warming potential. R32 has about a third of R410A’s warming impact and uses less gas per system, so manufacturers worldwide are moving new split ACs to it. For technicians and contractors in Kenya, that means more and more of your service work will be on R32 units. Bioflex will keep supplying R32 for new installations and R410A for the many systems already installed. Brands Available We stock R32 from Maxron and other leading brands, all in sealed factory cylinders. Tell us your preferred brand when you enquire and we’ll confirm availability. Why Buy R32 Gas from Bioflex Genuine, high-purity gas in sealed cylinders. No refilled or mixed gas. Several brands in stock Supply for installers, service technicians and AC contractors, from single cylinders to bulk orders Everything for the job in one place: R32, copper pipes, Armaflex insulation and tapes HVAC experience. Our team installs, maintains and repairs air conditioning. Pickup at Industrial Area, Nairobi, and delivery across Kenya and East Africa Safety and Storage R32 is mildly flammable. Store cylinders upright in a cool, well-ventilated place, away from heat, sparks and open flames. Keep cylinders out of direct sun and below 50 Β°C Never heat a cylinder with a flame Don’t store or charge R32 in basements or small closed spaces Wear gloves and goggles, because liquid refrigerant can cause frostbite Don’t vent R32 to the air. Recover it with A2L-rated equipment. Only trained, qualified technicians should install, charge or service R32 systems Other Refrigerant Gases We Supply R410A refrigerant gas for split and VRF air conditioners R22 refrigerant gas for servicing older air conditioners R407C refrigerant gas for chillers and R22 retrofits R134a refrigerant gas for car AC, fridges and chillers R404A refrigerant gas for cold rooms and freezers R507A refrigerant gas for cold rooms and blast freezers R600a refrigerant gas for household fridges You can also browse our full range of refrigerant gases in Kenya.

    R32 Refrigerant Gas

    R32 is a single-component refrigerant used in many new inverter split air conditioners. Its global warming potential is about a third of R410A, and systems need a smaller charge.

    • Lower GWP than R410A
    • Efficient and needs a smaller charge
    • Single-component gas

    Call or WhatsApp 0722 664 867 for a quote.

  • R404A refrigerant gas cylinder for cold rooms and freezers in Kenya

    R404A Refrigerant Gas

    R404A refrigerant gas in 11.3 kg cylinders for freezer rooms, cold rooms, supermarket display cabinets, ice machines and refrigerated trucks, available in Nairobi with delivery across Kenya.

    • For low and medium temperature refrigeration
    • Non-flammable and ozone-friendly
    • 11.3 kg net weight sealed cylinder

    Call or WhatsApp 0722 664 867 for a quote.

    .

  • R407A refrigerant gas cylinder for commercial refrigeration in Kenya

    R407C Refrigerant Gas

    R407C refrigerant gas in Kenya for air conditioners, chillers, heat pumps and packaged units. It’s also the most common ozone-safe replacement for R22. It’s non-flammable, in sealed cylinders from Maxron and other leading brands. Supply for AC contractors and maintenance teams, with pickup in Industrial Area, Nairobi, or delivery across Kenya and East Africa.

  • R410A refrigerant gas cylinder for air conditioners in Kenya

    R410A Refrigerant Gas

    R410A refrigerant gas in Kenya for split air conditioners, VRF/VRV systems, ducted units, and heat pumps. It’s an ozone-safe, non-flammable HFC blend, available from Maxron and other leading brands. Pickup in Industrial Area, Nairobi, or delivery across Kenya and East Africa.

  • R507A refrigerant gas cylinder for cold rooms in Kenya

    R507A Refrigerant Gas

    R507A is an azeotropic refrigerant blend for low-temperature refrigeration, such as freezer rooms, blast freezers, ice machines, and supermarket systems.

    • Designed for low temperatures
    • Behaves like a single gas
    • Sealed cylinders

    Call or WhatsApp 0722 664 867 for a quote.

  • R600a Refrigerant Gas (Isobutane) in Kenya

    R600a Refrigerant Gas (Isobutane)

    Refrigeration-grade R600a refrigerant gas (isobutane) for modern domestic fridges and freezers, available in Nairobi with delivery across Kenya.

    • Ozone-friendly with very low global warming potential
    • High purity, free from the impurities in cooking gas
    • For trained technicians, workshops and service companies

    Call or WhatsApp 0722 664 867 for a quote